How to handle P150 SRC4 remote controller the Unstable Controller Connection issue
P150 Drone – SRC4 Screen Connection Issue: Type-C Cable Contact Fix
1. Issue Description:
If you see both the [Battery Icon with Question Mark] and [Unstable Controller
Connection] warnings at the same time, the issue is usually caused by dust or poor
contact between the tablet screen and the controller body’s Type-C connection cable.
Follow the instructions below to reinstall and improve the USB connection.
2. Steps to Reinstall the Type-C Connection Cable
Step 1:
Remove the two screws securing the bracket that connects the screen to the controller.
Step 2:
After removing the screws, gently pull out the bracket to separate the screen from the
controller.
Step 3:
Clean the dust and debris from both the Type-C port and the groove area on the bracket.
Step 4:
Reinsert the screen firmly into the controller, ensuring the connection is fully seated,
then tighten the two screws from Step 1 securely.
Step 5:
If the same problem still occurs after cleaning the USB port, please replace the new screen
or exchange the screen for the customer. If the issue still cannot be solved, you can only
replace the remote control for the customer.